Abustek Technologies Inc. - Indicators, Controllers, Thermostats, Data Loggers, Transmitters
Abustek Technologies Inc. - Indicators, Controllers, Thermostats, Data Loggers, Transmitters

Abustek Technologies Inc. - Indicators, Controllers, Thermostats, Data Loggers, Transmitters

Abustek Technologies Inc. - Indicators, Controllers, Thermostats, Data Loggers, Transmitters
Abustek Technologies Inc. - Indicators, Controllers, Thermostats, Data Loggers, Transmitters
      Indicators
      Process Indicators
      Loop Powered Indicators
      Controllers
      Process Controllers
      On/Off Controllers
      Temperature Controllers
      Transducer/Transmitters
      Temperature Transmitters
      Pressure Transmitters
      Humidity+Temperature Transmitters
      Isolators/Distributors
      Temperature Instruments
      Data Logging & Acquisitions
      Digital Panel Instruments
Abustek Technologies Inc. - Indicators, Controllers, Thermostats, Data Loggers, Transmitters
Abustek Technologies Inc. - Indicators, Controllers, Thermostats, Data Loggers, Transmitters
 

equals

 

Abustek Technologies Inc. - Indicators, Controllers, Thermostats, Data Loggers, Transmitters
 

equals

 

Search  
Abustek Technologies Inc. - Indicators, Controllers, Thermostats, Data Loggers, Transmitters
On/Off Controllers
Abustek Technologies Inc. - Indicators, Controllers, Thermostats, Data Loggers, Transmitters
HOME PRODUCTS ON/OFF CONTROLLERS IB - 8 UNIVERSAL INDICATOR / CONTROLLER
     IB - 8 Universal Indicator / Controller
IB - 8 Universal Indicator / Controller

View Large

Input signal mA, V, mV, thermocouple and RTD selected by software; measuring range/Zero point can be adjusted.Two loops of relay alarm output. Capacity 250VAC/3A or 30VDC/5A.4-20mA analogue output.Auxiliary output power supply 24V/12V/30mA.W/ RS485 communication terminal.Accuracy: 0.3% FS.Applied for 2-loop transformer, pressure sensor, 4-loop weighing sensor, distance pressure meter, etc.

Abustek Technologies Inc. - Indicators, Controllers, Thermostats, Data Loggers, Transmitters
Power supply :   85V-260V AC/DC

Auxiliary power supply for sensor :   24V/12V DC max. 30mA isolate DC current or 12V/60mA auxiliary power

Alarm output :   High / low alarm output

Analog output :   4-20 mA Analog output

Accuracy :   0.3% FS

Communication terminal :   Standard RS485 interface

Dimension :   48H X 96W X 100L
Abustek Technologies Inc. - Indicators, Controllers, Thermostats, Data Loggers, Transmitters
[IB8_Indicator_Controller.pdf]